Optical distance measuring instrument

An optical instrument, such as a stability monitor or a target range finder, uses an unstabilized laser to project a composite optical signal of coherent light having two naturally occurring longitudinal mode components. A beamsplitter divides the signal into a reference beam which is directed toward one photodetector and a transmitted beam which illuminates and is reflected from a distant target onto a second photodetector optically isolated from the first photodetector. Both photodetectors are operated on the square law principle to provide electrical signals modulated at a frequency equal to the separation between the frequencies of the two longitudinal mode components of the optical signal projected by the laser. Slight movement of the target may be detected and measured by electrically monitoring the phase difference between the two signals provided by the photodetectors and the range of the target measured with the aid of a microprocessor by changing the separation between the longitudinal modes by shifting the length of the resonator cavity in an iterative series of increments.

Abshire, J. B.

Atmospheric refractivity corrections in satellite laser ranging

Atmospheric refraction can cause significant errors in satellite laser ranging (SLR) systems. There are two techniques which can be used to correct for these errors. Atmospheric models based upon surface measurements of pressure, temperature, and relative humidity have been shown by ray tracing to be accurate to within a few centimeters at 20 deg elevation angle. The residual errors in the models are thought to be primarily caused by horizontal gradients in the refractivity. Although models have been developed to predict the gradient effects, initial studies show that they can be sensitive to local topographic effects. Atmospheric turbulence can introduce random fluctuations in the refractivity, but only introduces centimeter level errors at elevation angles below 10 deg. Pulsed two-color ranging systems can directly measure the atmospheric delay in satellite ranging. These systems require mode-locked multiple-frequency lasers and streak-camera-based receivers and currently appear capable of measuring the atmospheric delay with an accuracy of 0.5 cm or better.

Abshire, J. B.

Performance of OOK and low-order PPM modulations in optical communications when using APD-based receivers

The paper computes direct detection laser communications receiver performance when using avalanche photodiode (APD) detectors. The performances are compared in terms of bit error probability vs average signal required per bit when the transmitter uses either on-off keying (OOK) or low-order PPM formats. It is shown that QPPM requires 3 dB less signal than OOK, while BPPM requires the same or slightly more than OOK for the same performance. Optimum APD gain values range from 200 to 400. When using QPPM, k(eff) = 0.006, and optimum gain, 60 signal counts/bit are required at 500 Mbits/s for a 0.000001 bit error probability. It is concluded that QPPM may be an attractive signaling format for some fiber or free space laser communication applications.

Abshire, J. B.

Self-Modulated Laser Rangefinder

Longitudinal resonance modes exploited. Self-modulated-laser ranging system exploits presence of signals differing in frequency by longitudinalmode separation frequency fm. Two square-law photodetectors have outputs modulated by fm, and phase difference between two outputs is related to target distance. Laser transmitter/receiver measures distances as well as displacements of distant objects (such as vibrating buildings).

Abshire, J. B.

Multicolor laser altimeter for barometric measurements over the ocean - Experimental

Measurement theory and results from testing a breadboard multiwavelength (355-, 532- and 1064-nm) laser altimeter over horizontal paths are presented. They show that pressure accuracies of 3 mbar can be achieved when ranging at nadir to cube corner targets when using a 500-psec resolution waveform digitizer and utilizing new calibration techniques. Streak camera-based receivers will be required for the same or higher accuracies when ranging to the ocean surface. System design calculations for aircraft and spaceborne experiments are presented.

Abshire, J. B.

Remote sensing of atmospheric pressure and sea state from satellites using short-pulse multicolor laser altimeters

Short pulse multicolor laser ranging systems are currently being developed for satellite ranging applications. These systems use Q-switched pulsed lasers and streak tube cameras to provide timing accuracies approaching a few picoseconds. Satellite laser ranging systems was used to evaluate many important geophysical phenomena such as fault motion, polar motion and solid earth tides, by measuring the orbital perturbations of retroreflector equipped satellites. Some existing operational systems provide range resolution approaching a few millimeters. There is currently considerable interest in adapting these highly accurate systems for use as airborne and satellite based altimeters. Potential applications include the measurement of sea state, ground topography and atmospheric pressure. This paper reviews recent progress in the development of multicolor laser altimeters for use in monitoring sea state and atmospheric pressure.

Gardner, C. S.

Geodetic distance measuring apparatus

A mode locked laser system including a laser device and its peripheral components is utilized for deriving two mutually phase locked optical wavelength signals and one phase locked microwave CW signal which respectively traverse the same distance measurement path. Preferably the optical signals are comprised of pulse type signals. Phase comparison of the two optical wavelength pulse signals is used to provide a measure of the dry air density while phase comparison of one of the optical wavelength pulse signals and the microwave CW signal is used to provide a measure of the wet or water vapor density of the air. From these measurements is computed in means of the distance to be measured corrected for the atmospheric dry and water vapor densities in the measurement path.

Abshire, J. B.

Rangefinder Corrects for Air Density and Moisture

Proposed distance-measuring instrument compensates for variations in both dry atmospheric density and water-vapor content. Instrument would be expected to be more accurate than previous laser-ranging instruments. New rangefinder sends three signal trains to target: Two trains are at optical frequencies, and one is at a microwave frequency. All three signals are phase-locked.

Abshire, J. B.

Pulsed multiwavelength laser ranging system

A pulsed multiwavelength laser ranging system for measuring atmospheric delay was built and tested, and its theoretical performance limits were calculated. The system uses a dye modelocked ND:YAG laser, which transmits 70 psec wide pulses simultaneously at 1064, 532, and 355 nm. The differential delay of the 1064 and 355 nm pulses is measured by a specially calibrated waveform digitizer to estimate the dry atmospheric delay. The delay time of the 532 nm pulse is used to measure the target distance. Static crossed field photomultipliers are used as detectors for all wavelengths. Theoretical analysis shows that path curvature and atmospheric turbulence are fundamental limits to the ranging accuracy of both single and multicolor systems operating over horizontal paths. For two color systems, an additional error is caused by the uncertainty in the path averaged water vapor. The standard deviation of the multicolor instrument's timing measurements is directly proportional to the laser pulse width plus photomultiplier jitter divided by the square root of the received photoelectron number. The prototype system's maximum range is km, which is limited by atmospheric and system transmission losses at 355 nm. System signal detection and false alarm calculations are also presented.

Abshire, J. B.

Geodetic distance measuring apparatus

A geodetic distance measuring apparatus which compensates for the refractive index of the atmosphere is discussed. A mode locked laser system with a laser device and its peripheral components is utilized to derive two mutually phase locked optical wavelength signals and one phase locked microwave CW signal which respectively traverse the same distance measurement path. The optical signals are comprised of pulse type signals. Phase comparison of the two optical wavelength pulse signals is used to provide the dry air density while phase comparison of one of the optical wavelength pulse signals and the microwave CW signal issued to provide wet or water vapor density of the air. The distance to be measured corrected for the atmospheric dry air and water vapor densities in the measurement path is computed from these measurements. A time interval unit is included for measuring transit time of individual optical pulses for resolving the phase ambiguity needed with the phase measurements to give the true target distance.

Abshire, J. B.

Pulsed multiwavelength laser ranging system for measuring atmospheric delay

A multiwavelength laser ranging system has been designed for measuring atmospheric path delay in satellite laser ranging systems. The instrument measures the difference between the propagation times of 532 and 355 nm pulses as a measure of integrated air density. The present design uses a frequency-tripled dye mode-locked Nd:YAG laser as a pulse source and subnanosecond response time photomultipliers as detectors. Studies indicate that recovery of the atmospheric path delay in satellite ranging to the 1-cm level will require the differential arrival time measurements with an accuracy of 3-7 ps. Initial horizontal path test results are presented.

Abshire, J. B.

Circular-scan streak tube with solid-state readout

A circular-scan streak tube designed for use in a laser ranging system is described. Electrostatic focusing is used between the photocathode and a microchannel plate, and electrons from the microchannel plate are proximity focused onto an output phosphor screen. Electron beam deflection is achieved by driving two orthogonal sets of deflection plate assemblies in phase quadrature at a frequency of 200 MHz. The light intensity in the output beam trace is measured by using a circular Reticon array of 720 photodiodes, which is fiber-optically coupled to the output phosphor screen of the tube. Sample measurements of frequency-doubled Nd:YAG laser-pulse waveforms are given. Also the output beamwidth has been measured at the 200-MHz deflection frequency. The results suggest a limiting resolution of 33 psec for the circular-scan streak tube used for these tests.

Johnson, C. B.

A comparative study of optimum and suboptimum direct-detection laser ranging receivers

A summary of previously proposed receiver strategies for direct-detection laser ranging receivers is presented. Computer simulations are used to compare performance of candidate implementation strategies in the 1- to 100-photoelectron region. Under the condition of no background radiation, the maximum-likelihood and minimum mean-square error estimators were found to give the same performance for both bell-shaped and rectangular optical-pulse shapes. For signal energies greater than 100 photoelectrons, the root-mean-square range error is shown to decrease as Q to the -1/2 power for bell-shaped pulses and Q to the -1 power for rectangular pulses, where Q represents the average pulse energy. Of several receiver implementations presented, the matched-filter peak detector was found to be preferable. A similar configuration, using a constant-fraction discriminator, exhibited a signal-level dependent time bias.

Abshire, J. B.

Prelaunch testing of the GEOS-3 laser reflector array

The prelaunch testing performed on the Geos-3 laser reflector array before launch was used to determine the lidar cross section of the array and the distance of the center of gravity of the satellite from the center of gravity of reflected laser pulses as a function of incidence angle. Experimental data are compared to computed results.

Minott, P. O.

A system for measuring the pulse height distribution of ultrafast photomultipliers

A system for measuring the pulse height distribution of gigahertz bandwidth photomultipliers was developed. This system uses a sampling oscilloscope as a sample-hold circuit and has a bandwidth of 12 gigahertz. Test results are given for a static crossed-filed photomultiplier tested with a demonstration system. Calculations on system amplitude resolution capabilities are included for currently available system components.

Abshire, J. B.

Characterization of gigahertz (GHz) bandwidth photomultipliers

The average impulse response, root-mean-square times jitter as a function of signal level, single photoelectron distribution, and multiphotoelectron dark-count distribution have been measured for two static crossed-field and five electrostatic photomultipliers. The optical signal source for the first three of these tests was a 30 picosecond mode-locked laser pulse at 0.53 micron. The static crossed-field detectors had 2-photoelectron resolution, less than 200 ps rise times, and rms time jitters of 30 ps at the single photoelectron level. The electrostatic photomultipliers had rise times from 1 to 2.5 nanoseconds, and rms time jitters from 160 to 650 ps at the same signal level. The two static crossed-field photomultipliers had ion-feedback-generated dark pulses to the 50-photoelectron level, whereas one electrostatic photomultiplier had dark pulses to the 30-photoelectron level.

Abshire, J. B.

Systems for measuring response statistics of gigahertz bandwidth photomultipliers

New systems have been developed for measuring the average impulse response, the pulse-height spectrum, the transit-time statistics as a function of signal level, and the dark-count spectrum of gigahertz bandwidth photomultipliers. Measurements showed that the 0.53 microns pulse used as an optical test source had a 30 picoseconds and less than 70 ps pulse width. Calibration data showed the system resolution to be less than 20 ps for root mean square transit-time measurements. Test data for a static crossed-field photomultiplier showed 2-photoelectron resolution and less than 30-ps time jitter over the 1- to 100-photoelectron range.

Abshire, J. B.

Prelaunch testing of the laser geodynamic satellite (LAGEOS)

The LAGEOS was extensively tested optically prior to launch. The measurement techniques used are described and resulting data is presented. Principal emphasis was placed on pulse spreading characteristics, range correction for center of mass tracking, and pulse distortion due to coherent effects. A mode-locked freqeuncy doubled Nd:YAG laser with a pulse width of about 60 ps was used as the ranging transmitter and a crossfield photo-multiplier was used in the receiver. High speed sampling electronics were employed to increase receiver bandwidth. LAGEOS reflected pulses typically had a width of 250 ps with a variability in the range correction of less than 2 mm rms. Pulse distortion due to coherent effects was inferred from average waveforms and appears to introduce less than + or - 50 ps jitter in the location of the pulse peak. Analytic results on this effect based on computer simulations are also presented. Theoretical and experimental data on the lidar cross section were developed in order to predict the strength of lidar echoes from the satellite. Cross section was measured using a large aperture laser collimating system to illuminate the LAGEOS. Reflected radiation far-field patterns were measured using the collimator in an autocollimating mode. Data were collected with an optical data digitzer and displayed as a three-dimensional plot of intensity versus the two far-field coordinates. Measurements were made at several wavelengths, for several types of polarizations, and as a function of satellite orientation.

Fitzmaurice, M. W.