Engineering PapersSearch

Engineering topics

Abedian, B.

Publications and source records attributed to Abedian, B..

Laminar-Turbulent Transition in an Electromagnetically-Levitated Droplet

During experiments on the MSL-1 (First Microgravity Science Laboratory) mission of the Space Shuttle (STS-83 and STS-94, April and July 1997), a droplet of palladium-silicon alloy was electromagnetically levitated for viscosity measurements. For the non-deforming droplet, the resultant MHD flow inside the drop can be inferred from motion of impurity particulates on the surface. In the experiments, subsequent to melting, Joule heating produces a continuous reduction of viscosity of the fluid resulting in an acceleration of the flow with time. These observations indicate formation of a pair of co-rotating toroidal flow structures inside the spheroidal drop that undergo flow instabilities. As the fluid temperature rises, the amplitude of the secondary flow increases; and beyond a point, the tracers exhibit non-coherent chaotic motion signifying emergence of turbulence inside the drop. Assuming that the observed laminar-turbulent transition is shear-layer type, the internal structure of the toroidal loops is used to develop a semi- empirical correlation for the onset of turbulence. Our calculations indicate that the suggested correlation is in modest agreement with the experimental data, with the transition occurring at a Reynolds number of 600.

Hyers, R. W.

Surface Oscillations of An Electromagnetically Levitated Droplet

Oscillating droplets are of interest in a number of disciplines. A practical application is the oscillating drop method, which is a technique for measuring surface tension and viscosity of liquid metals. It is especially suited to undercooled and highly reactive metals, because it is usually performed by electromagnetic levitation. The natural oscillation frequency a f the droplets is related to the surface tension of the material, and the decay of oscillations is related to its viscosity. The fluid flow inside the droplet must be laminar in order for this technique to yield good results. Because no experimental method has yet been developed to visualize flow in electromagnetically-levitated oscillating metal droplets, mathematical modeling is required to determine whether or not turbulence occurs. Three mathematical models of the flow: (1) assuming laminar conditions, (2) using the turbulence model, and (3) using the RNG turbulence model, respectively, are compared and contrasted to determine the physical characteristics of the flow. It is concluded that the RNG model is the best suited for describing this problem. The goal of the presented work was to characterize internal flow in an oscillating droplet of liquid metal, and to verify the accuracy of the characterization by comparing calculated surface tension and viscosity values to experimentally-obtained results.

Berry, S.

Spin-Up Instability of a Levitated Molten Drop in MHD-Flow Transition to Turbulence

When an alternating magnetic field interacts with induced eddy currents in a conducting body, there will be a repulsive force between the body and the driving coil system generating the field. This repulsive force is the basis of electromagnetic levitation, which allows containerless processing of different materials. The eddy currents in the conducting body also generate Joule heating. Axial rotation of electromagnetically levitated objects is a common observation in levitation systems and often an undesirable side effect of such experiments on 1-g and -g. There have been recent efforts to use magnetic damping and suppress this tendency of body rotation. The first report of rotation in EML drops was attributed to a slight asymmetry of the shape and location of the levitation coils could change the axis and speed of rotation. Other theories of sample rotation include a frequency difference in the traveling electromagnetic waves and a phase difference in two different applied fields of the same frequency. All of these different mechanisms share the following characteristics: the torque is small, constant for constant field strength, and very weakly dependent on the sample's temperature and phase (solid or liquid). During experiments on the MSL-1 (First Microgravity Science Laboratory) mission of the Space Shuttle (STS-83 and STS-94, April and July 1997), a droplet of palladium-silicon alloy was electromagnetically levitated for viscosity measurements. For the non-deforming droplet, the resultant MHD flow inside the drop is inferred from motion of impurities on the surface. These observations indicate formation of a pair of co-rotating toroidal flow structures inside the spheroidal levitated drop that undergo secondary flow instabilities. As rise in the fluid temperature rises, the viscosity falls and the internal flow accelerates and becomes oscillatory; and beyond a point in the experiments, the surface impurities exhibit non-coherent chaotic motion signifying emergence of turbulence inside the drop. In this work, a background of these set of observations will be given followed by a presentation of our results on the digital particle tracking analysis that has been performed on a number of available videos. The analysis indicates that the levitated drop attains a constant rotational speed during the melting phase and formation of the co-rotating axi-symmetric laminar toroidal structures. However, the rate of axial rotation increases dramatically during the deformation of the toroidal structures anti their breakup into chaotic entities. This new data suggests an interaction between the flow inside the levitated molten drop and the driving coils in the experiments. Possible mechanisms for this interaction will be reviewed. The data will also be used to make an assessment of existing theories on droplet rotation.

Abedian, B.

Modeling of Turbulent Flow in Electromagnetically Levitated Metal Droplets

This article details an effort to improve the understanding and prediction of turbulent flow inside a droplet of molten metal levitated in an electromagnetic field. It is shown that the flow field in a test case, a nickel droplet levitated under microgravity conditions, is in the transitional regime between laminar and turbulent flow. Past research efforts have used laminar, enhanced viscosity, and k-epsilon turbulence models to describe the flow. The method highlighted in our study is the renormalization group (RNG) algorithm. We show that an accurate description of the turbulent eddy viscosity is critical in order to obtain realistic velocity fields, and that the turbulent eddy viscosity cannot be uniform in levitated droplets. The RNG method does not impose isotropic length or time scales on the flow field, thus allowing such nonuniform features to be captured. A number of other materials processing applications exhibit similarly complex flow characteristics, such as highly recirculating, transitional, and free surface flows, for which this modeling approach may prove useful.

Berry, S.

Mathematical Modeling of an Oscillating Droplet

Oscillating droplets are of interest in a number of disciplines. A practical application is the oscillating drop method, which is a technique for measuring surface tension and viscosity of liquid metals. It is especially suited to undercooled and highly reactive metals, because it is performed by electromagnetic levitation. The natural oscillation frequency of the droplets is related to the surface tension of the material, and the decay of oscillations is related to its viscosity. The fluid flow inside the droplet must be laminar in order for this technique to yield good results. Because no experimental method has yet been developed to visualize flow in electromagnetically-levitated oscillating metal droplets, mathematical modeling is required to determine whether or not turbulence occurs. Three mathematical models of the flow: (1) assuming laminar conditions, (2) using the k-epsilon turbulence model, and (3) using the RNG turbulence model, respectively, are compared and contrasted to determine the physical characteristics of the flow. It is concluded that the RNG model is the best suited for describing this problem. The goal of the presented work was to characterize internal flow in an oscillating droplet of liquid metal, and to verify the accuracy of the characterization by comparing calculated surface tension and viscosity.

Berry, S.

Turbulent Transition in Electromagnetically Levitated Drops

Electromagnetic levitation (EML) is an important tool in materials research. Because a sample can be processed without contact with a container, experiments may be performed on high temperature, highly reactive, and undercooled liquid metals. Many of these experiments are affected by fluid flow in the sample, driven by the electromagnetic positioning force. Despite the importance of convection in these experiments, the transition to turbulence is not well understood in this system. However, we have observed a transition from laminar to turbulent flow in EML droplets in the course of microgravity experiments in TEMPUS on the Space Shuttle (STS-94). The transition occurs repeatably and over a narrow range of conditions. These experimental observations are compared with two competing theories about the transition to turbulence. Also, the results of a particle tracking study of the instabilities leading up to the transition to turbulence are presented.

Hyers, Robert W.

Transition to Turbulence in an Electromagnetically-Levitated Droplet

During experiments on the MSL-1 (First Microgravity Science Laboratory) mission of the Space Shuttle (STS-83 and STS-94, April and July 1997), a transition to turbulence in an electromagnetically levitated droplet was observed. Until the present time, there has been no information available on the flow state inside electromagnetically-levitated droplets. A new criterion for transition to turbulence in levitated droplets has been developed, and the experimentally observed behavior provides direct experimental verification of the theory.

Hyers, R. W.