Engineering Papers⌕ Search

Engineering topics

Abdelaziz, Omar

Publications and source records attributed to Abdelaziz, Omar.

At least 19 records

Benefits and challenges in deployment of low global warming potential R290 refrigerant for room air conditioning equipment in California

High global warming potential gases (“high GWP”) are the fastest growing sector of greenhouse gas emissions in the world and in California and are primarily used as refrigerant gases in refrigeration and cooling equipment. Hydrofluorocarbons (HFCs) refrigerants are the dominant type of high GWP gases with GWP values thousands of times larger than CO 2 on a 100-year timescale. Refrigerant-grade propane (“R290”) has a very low GWP (GWP = 3.3) with good thermodynamic properties and good cooling equipment performance but the flammability of any leaked refrigerant makes equipment design, handling, and maintenance critical factors to manage. This paper focuses on the potential climate benefits and costs of transitioning to R290 refrigerant in small room air conditioning (AC) units, specifically window AC, packaged terminal AC/heat pumps (PTAC/PTHP), and mini-split heat pumps. Overall climate impact for a transition to all three types of air conditioning units in the 2022–2051 timeframe is found to be from 15 to 64 million metric tons of greenhouse gas (GHG) savings in California with a cost of saved CO 2 eq that ranges from $14.50 per ton of CO 2 eq saved to -$50.30 per ton of CO 2 eq saved (net savings) depending on whether the baseline refrigerant is R32 or R410A and depending on the relative energy efficiency for R290 units compared to baseline units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling system utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

Design and Manufacturing of High Performance, Reduced Charge Heat Exchangers

A framework of stress analysis and fatigue analysis was developed. Utilizing the framework, stress analysis and fatigue analysis of high-performance heat exchangers with non-round shaped tubes were studied. The tubes, headers and welding layers were studied separately before analyzing the assembled heat exchangers. Results reveal different stress strength on the different shapes of tubes and headers. Unevenly welding distribution is also discussed in the report. Moreover, the fatigue analysis results of the heat exchanger are helping to estimate the lifetime of the heat exchanger from fatigue point of view.

42 ENGINEERING↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling systems utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

Method and device for controlling heat pump

A method for controlling a heat pump is provided. A working mode of the heat pump is determined. Based on a determination that the working mode of the heat pump is a heating mode, an ambient temperature of the heat pump is determined. Based on a determination that the ambient temperature of the heat pump is higher than a first predetermined temperature, a first compressor of the heat pump is operated. Based on a determination that the ambient temperature of the heat pump is lower than the first predetermined temperature, both the first compressor and a second compressor of the heat pump are enabled to operate, in response to a two-stage thermostat. The first compressor and the second compressor are coupled in parallel. The method allows the heat pump to be suitable for a cold climate.

42 ENGINEERING↗

Critical Material Supply Chain Analysis: Magnetocalorics

Understanding manufacturing cost and supply chain implications of technologies is critical to aid adoption of next-generation energy solutions, such as advanced heating ventilation and air conditioning (HVAC) equipment for building energy efficiency. This report provides insights into the market, regulatory, technology, and cost drivers most impacting the adoption of magnetocaloric refrigeration (MCR) systems in the U.S., with a focus on the rare earth materials requirements, manufacturing costs of key components, and detail on the supply chain of critical materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Refrigerants: Market Trends and Supply Chain Assessment

The National Renewable Energy Laboratory (NREL), in partnership with ORNL, under the Clean Energy Manufacturing Analysis Center (CEMAC www.manufacturingcleanenergy.org) umbrella, assessed the current state of existing and low-GWP refrigerants for major end-use applications, including HVAC and those outside of the HVAC industry. The project incorporated a market overview, and supply chain assessment to determine the production, distribution, consumption, costs, and potential operating efficiency impacts of new and alternative refrigerants entering the market. Market trends and ongoing research are also documented. This work supplements other DOE efforts to support research activities on refrigerants and their applications including a refrigerant R&D roadmap and outlook into global air conditioning markets (Goetzler et al. 2014, 2016).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetocaloric refrigeration using fully solid state working medium

A magnetocaloric cooling system comprising a solid body or bodies, such as a cylinder or cube, having a plurality of channels extending between a first end and a second end of the cylinder or cube and a magnet at least partially surrounding the cylinder or cube. A metallic mass, such as a rod or plate, is positioned within each channel and slides within a respective channel between two sliding extremities so that in each sliding extremity, a portion of each metallic mass extends beyond an end of the solid body. A motor is used for reciprocating the metallic masses between the sliding extremities and a heat exchange mechanism directs heating or cooling where desired.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Risk Assessment of Catastrophic Leak Of R-452b From Package Unit into A Residential Space

With the effort to find alternative refrigerants with lower global warming potential (GWP), challenges have arisen due to the flammability risk for many of the alternatives. One of the new alternatives is R-452B, which is recommended as a replacement for R410A. R-452B is classified as a mildly flammable refrigerant (A2L) by ANSI/ASHRAE Standard 34. This paper summarizes a computational fluid dynamic (CFD) simulation study of a leak incident of R-452B from a 3-ton packaged unit which serves a 167 m 2 residence. The R-452B leak is assumed to be downstream of the evaporator coil. The simulated residence has four rooms and a hallway. The packaged unit distributes the conditioned air through a supply duct system delivering the air through registers. The dispersion of R-452B is characterized for two scenarios: one with underfloor supply air ducts and another with ceiling supply air ducts. The mass flow rate of R-452B exiting the duct outlets is quantified and the refrigerant volume fraction is monitored inside the residential space.

42 ENGINEERING↗

Development and case study of the liquid desiccant system module in sorption system simulation program (SorpSim)

Liquid desiccant systems (LDS) have recently seen an increase in research interest as they can utilize low-grade heat resources and separate the sensible and latent cooling loads by efficiently removing moisture in the air without cooling it to the dew point. Yet, simulation and analysis of LDS had remained complex and demanding due to the limited resources of LDS simulation tools. This work presents the new LDS module developed in the Sorption system Simulation program (SorpSim), which is an open-source and flexible platform for steady-state simulation and analysis of various sorption systems. First, the new LDS module containing a finite-difference model and an effectiveness-NTU model for the heat and mass transfer in LDS dehumidifier/regenerator component was introduced. Then the simulation results of the new module were verified using data from the literature. Lastly, a case study was carried out in SorpSim where an LDS cycle was built and simulated using the new module. The impacts of design and operating parameters on the simulated LDS performance were investigated. The parametric study revealed that a high source temperature improved moisture removal rate (MRR) but reduced the system coefficient of performance (COP); the COP increased monotonically with the desiccant solution recirculation ratio, while the MRR peaked at a ratio of 85%; and an internal solution heat exchanger with UA of 800 W/K was found to be sufficient for optimal performance under high recirculation ratios. The case study demonstrated the LDS module’s capability to facilitate the analysis of LDS design and operation. The LDS module can be further coupled with other component models in SorpSim to simulate and analyze various liquid-desiccant-based systems.

42 ENGINEERING↗

Reduced-order model to estimate safe flammable refrigerant charge limits for a one-room air conditioner

The Heating, Ventilation, Air-Conditioning and Refrigeration (HVAC&R) industry is currently transitioning away from high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants. However, many lower-GWP alternatives are flammable. Current safety codes restrict use of all flammable refrigerants; revision of the codes is needed to facilitate wider use of flammable alternatives. Hence, information is needed to enable reliable estimates of safe charge limits for flammable refrigerant options for different HVAC&R applications. A reduced-order model (ROM) was developed and validated to help estimate safe charge limits based on computational fluid dynamics (CFD) simulations of refrigerant releases in a single room for a range of parameters. Validation of the ROM vs. the CFD results showed good general agreement for mean refrigerant concentration. The normalized mean bias error (NMBE) was 0.67% with a maximum error of 15%.

Edwards, Dean↗

Hydrocarbons as natural refrigerants for heat pump water heating applications

Growing awareness of the potential environmental impacts of conventional refrigerants (CFCs and HFCs) has led to efforts to identify suitable refrigerants for various heat pump applications with minimum environmental impact. This study is focused on the performance evaluation of pure propane and isobutane as drop-in-replacement for R134a for heat pump water heating (HPWH). A component-based model is used to predict the performance. Key performance parameters such as unified energy factor, first hour rating and thermal stratification in the water tank are investigated. Appropriate experiments are conducted to validate the finding from model. Simulation and experimental findings suggest that both alternative refrigerants could provide comparable system performance to that of the baseline system containing R134a. System refrigerant charge and the condenser discharge temperature are established to investigate the potential of hydrocarbon refrigerants to substitute R134a without significant system modifications.

Nawaz, Kashif↗

Methodology for Estimating Safe Charge Limits of Flammable Refrigerants in HVAC&R Applications - Part 2

This report provides a detailed description of the development of a reduced order model (ROM) that could be used for estimation of safe charge limits based on a computational fluid dynamics (CFD) parametric study. The ROM was developed to simulate leak events from a single side-wall duct penetration into a room and provide estimates of refrigerant concentration together with flammable volume fraction (FVF), accumulated fuel volume (AFV) and other outputs vs. time. The ROM is based on a range of seven parameters listed in Table ES1 and assumes that the AC unit air circulation blower is off. A total of 586 CFD “training” cases were run and used as the basis for development and training or calibration of the ROM. The regression analysis used to develop the ROM was performed in Tasmanian ( T oolkit for A daptive S tochastic M odeling A nd N on- I ntrusive A pproximatio N ). This is a tool developed at ORNL for high-dimensional integration, interpolation and parameter calibration. Comparison of the ROM vs. several CFD test cases (at points not used in the training set) showed maximum absolute and root mean square errors (RMSE) for FVF of 1.32% and 0.5%, respectively. Initial CFD runs were conducted to gauge the sensitivity of the results to each parameter. Based on the findings, the numbers of design of experiment (DoE) levels for each parameter was determined. Then, for each parameter, Tasmanian calculated the value of each level and defined a DoE of 586 unique CFD simulation cases.

42 ENGINEERING↗

Image-Guided Percutaneous Bleomycin and Bevacizumab Sclerotherapy of Orbital Lymphatic Malformations in Children

Purpose: To evaluate the effectiveness and safety of image-guided percutaneous sclerotherapy using bleomycin for macrocystic and bevacizumab (Avastin™) for microcystic orbital lymphatic malformations in children. Materials and Methods: Between October 2015 and July 2018, we prospectively evaluated 10 pediatric patients who presented clinically and radiologically with lymphatic malformations and were treated with percutaneous sclerotherapy. Patients with venous malformations were excluded. Eight females and two males with ages ranging from 3 to 17 years (mean: 8.8, SD: 4.9) were included. Guided with ultrasound and fluoroscopy, macrocysts were treated with bleomycin instillation. For microcystic components in three patients, bevacizumab was injected intralesional. All patients underwent ultrasound and non-contrast MRI to evaluate response to treatment after 6 weeks. Results: The malformations were macrocystic in seven patients and complex (macro/microcystic) in three. Twenty sclerotherapy sessions were performed, (range: 1–3 sessions, mean: 2, SD: 0.8). Clinically, there was a significant reduction in the proptosis after treatment (P = 0.007) and dystopia (P = 0.018). The local radiological response showed a reduction in the maximum lesions diameters and volumes after treatment (P = 0.005 and 0.005, respectively). Two of the three patients treated with bevacizumab showed a reduction in the lesions volumes by 90.4% and 63.4%, respectively, whereas one patient did not show volume reduction. Transient periorbital edema and ecchymosis occurred following the procedure with no major complications encountered. Follow-up ranged from 9–33 months, mean: 20.3, SD: 7.4. Conclusion: Bleomycin sclerotherapy is a safe and effective treatment for orbital macrocystic lymphatic malformations. Further use of bevacizumab for microcystic lesions in a larger series is required to outline its efficacy and safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Open absorption cycle for combined dehumidification, water heating, and evaporative cooling

An absorption cycle system, which permits water heating, dehumidifying, and/or evaporative cooling, includes a desorber, absorber, heat exchanger, and, optionally, an evaporator, is constructed to heat a process water that is plumbed through the absorber, heat exchanger, and condenser. In the absence or isolation of the evaporator, the system can dehumidify ambient air to the absorber. The water vapor released by evaporative cooling at the evaporator can be provided to the absorber in a controlled manner to simultaneously maintain a desired humidity while cooling the air ambient by the evaporator. The absorption cycle system can be housed within a single unit or can be compartmentalized.

42 ENGINEERING↗

Flammable Refrigerant Charge Limits: Can or Should These Limits Be Higher?

A workshop was held to discuss different aspects of the application of flammable refrigerants in refrigeration and air conditioning equipment. The participants included stakeholders from industry, regulatory bodies, and the scientific community. The goal was to solicit feedback on the critical scientific, regulatory and practical issues for safe employment of flammable refrigerants in heating, ventilation, air- conditioning and refrigeration equipment. This paper reports on the outcome of the workshop and presents review of relevant past studies when available. The reported outcome may serve well as a guide to further research needed as adoption of flammable refrigerants increases.

42 ENGINEERING↗